I noticed my home gas furnace was turning on, I could hear it running, but it seemed the fan was not blowing the heat out of the heat duct vents SO I went downstairs to the furnace, and looked at the red blinking light on my American Standard Freedom 80 furnace, and it showed 4 blinking flashes then a pause, so I looked on the error chart on the front panel, and it said "Open high limit device.

Anyways, while I was there at the furnace, I figured I would jiggle the 2 electrical connections that connect to the fan housing. I just tried to get the metal on metal connection of the electrical connectors to seat slightly differently.

I put the front panel back on, and the system fired up, and this time I could hear the fan running and blowing the hot air. I went upstairs, and yes, the heat vents had blowing hot air.

Anyways, in the days before this I had been smelling an odd "electrical burning" smell, like a smell I had smelled before when I had a motor burn out, in some other unrelated tool. I'm just guessing that this smell is related to the new problem with the furnace? The filter was replaced one month ago. Well, I was wondering if you could suggest some helpful hints and knowledge?

I sure would appreciate being able to learn. Does "open high limit device" error code mean that the device is stuck open? What do you think the "burning" smell is coming from? Which part would be affected in such a way as to cause this? A "high limit" switch protects the furnace against overheating and damage -- it's located in the output duct, or plenumof the furnace and turns the furnace off if things get too hot up there.

The usual cause of a high limit trip is inadequate airflow -- in your case, because an apparently faulty connection was causing the fan to not run.

If you continue to get the "electrical burning" smell after fixing the connections -- that's a sign the fan motor on your furnace is on the way out the door. Generally, you'll need to have an HVAC service tech come in and swap it for a replacement. If you can access the other side of the connection, you can also use a voltmeter to measure the voltage drop across it -- anything more than a volt is cause for serious concern.

I had the same thing. I checked both limit switches with a meter and the primary limit switch was open, but closed once it cooled off. It would heat up, light for a few minutes but the blower never turned on.

This caused it to overheat so the induction blower turned on and stayed on to cool it off. This ind blower would not turn off until I unplugged it. An hvac guy I know said to buy American because it will last longer. The capacitor is attached to the blower housing. Watch videos on how to change it.When lit, this red light, also called a lockout light, indicates that a safety mechanism on your furnace has caused a shutdown because it has detected a problem or recognized a fault.

Note: Not all furnaces have this red light. Some have a red reset button that does not light up. The most common trigger for a shutdown is the absence of a flame when the burner kicks on, but there are many other causes, or it may just be a fluke. If your furnace has a digital display that provides a fault code, you can easily check the fault code to diagnose the problem.

Make sure you have oil in your tank. Make sure the oil valve is open. A closed oil valve prevents oil from getting to the burner and will prevent the burner from firing. When no flame is detected, the furnace will shut down.

After checking your oil supply and oil valve, press the reset button. Press and release the reset button to see if the furnace will fire. If it does, and this happens only once, it was probably a fluke. Call a professional, as this is a sign of a more serious problem. Automatic shutdown of your furnace is a safety feature designed to protect you and to keep your furnace from experiencing additional damage beyond whatever condition caused it to shutdown in the first place. Your service technician will make sure all of the components are clean and functioning properly, which will give you peace of mind throughout the heating season.

It has been designed to create an opportunity for both producers and distributors to present their business value and products worldwide. One system allowing for global reach. Share your catalogues, software selection programs and all business facts you consider important.

It is a great place to present all your products at once effortlessly. Each product is equipped with an option "Add to inquiry" for customer convenience. A customer sends an inquiry directly to you. Basically speaking, aeroventic is an equivalent of offline trade fair where you present your company and products, distribute catalogues, make contacts and develop your business.

What is aeroventic? Company profile Build your company value and present your competitive advantage. Product virtual showroom It is a great place to present all your products at once effortlessly. What You Get with us? Continue browsing Send an inquiry.A person can read Trane furnace codes by looking at sites such as FurnaceReviews.

A Trane furnace shows the owner that there is an issue within the furnace by using a red blinking light. The number and type of blinks indicate the problem. If the red light on a Trane furnace is blinking slowly, there is no problem with the furnace, but if it flashes quickly, it means there is no heat. If the light stays on, the furnace needs a new integrated furnace controller.

If the light flashes two times, the furnace is indicating a system lockout. Three flashes from a Trane furnace indicates a draft pressure error, which means there could be a venting issue, inducer problems or pressure switch problem. If there are four flashes, the furnace is indicating an open temperature limit circuit, and if there are five flashes, the system is sensing a flame, but no flame should be found.

If there are six flashes from a Trane furnace, it indicates the volt AC power is reversed, there is poor grounding or the system voltage too low.

Seven flashes from the system show that there is a gas valve circuit error, and eight flashes means the low flame sense signal has gone off. When there are nine flashes, the system is indicating some type of grounding problem.

Home World View. How Long Does a Furnace Last?Dan has been in the HVAC industry for 23 years with experience ranging from installation and service to sales and distribution. Furnaces of today all come equipped with an LED light mounted to the circuit board. No, it's not there so you can find it in the dark. It's there to help you understand what your furnace is doing.

Problems With Trane XR80 Furnaces

Whether it's working just fine or if it's completely kaput, this light is the voice of your furnace and if you don't speak its language then well, you're just not bonding with your unit as you should. This article will explain how to read the light codes, interpret them, and understand what your furnace problem might be should you have one. Feel free to have a look at my article troubleshooting your furnace for some easy to understand, but a bit more in-depth, help with your issue.

First, I'll explain how to understand the light and identify the code it's giving you. Then, I'll give advice based on the type of code you've gotten. This article is general knowledge that applies to most furnace brands. Surely you've heard of Morse Code. Well, your furnace uses a similar dash and dot system.

Of course, it's not giving you the letters of words. Instead, it tells you a number that is a code for a specific type of problem that you can look up. If it's a single digit, it will repeat the same dot pattern over and over with short pauses in between, like dot, dot, dot, pause, dot, dot, dot, pause.

This would be a "3. If it's a double digit number, it will use a dot, pause, dash, pause pattern to guide you on your way, like this: dot, dot, dot, pause, dash, dash, dash, pause, dot. This would be a " Well, each furnace with this feature will have a code chart for you to refer to with your newfound knowledge.

Most often this chart is found right on the furnace compartment doors for your convenience. For some, however, you may have to refer to your owner's manual. Here's a list of some major furnace brands and their codes. If you can't find it anywhere you can check online, call a supplier, or even call the manufacturer directly. Have your make and model ready if doing so to speed up your search and ensure you get accurate information. Now that you've gotten the code and referred to the troubleshooting chart for its meaning, it's time to see what the problem is.

That takes a bit more knowledge. You see, this light isn't a miracle worker. It's job is basically to point out the source of your furnace's problem. It's up to you to take it from there. The following will help you know where to look and what you should be looking for when trying to pinpoint your furnace issue.

If you know you have this light but it's not on, you are either not getting power to the unit check your breakers and service switch or you've blown the fuse on the circuit board. The good news is that these are all simple furnace problems to fix, and the latter of the two is certainly the more common.

You wouldn't believe how often fuses can blow. I always keep a few 3 amp fuses around for this reason.Lennox Elite Furnace Issues Slow blinking green light. Thread: Lennox … The error code is a single green slow flashing light. The sticker says. The error code is a single green slow flashing light. If both lights alternate and flash slowly, the furnace may have a damaged or disconnected flame sensor or sensor wire. Cold and noticing blinking lights on your Lennox furnace?

And I need model from furnace…the one supplied is for an ac coil. The green light on the ignition control board 60M32 keeps flashing and … If it does not complete the call for heat, leave the furnace on for while.

Gas Furnace Limit Switch Troubleshooting & Replacement

Make sure you definitely stay up on the filter for this furnace and avoid pleated filters. A complete Lennox furnace repair guide, from how to replace your air filter … Lennox furnaces are equipped with two LED lights that will flash in. Here are error codes found on many Arco, York, Trane, Luxaire, Lennox, Carrier, Coleman and … 2 green colored flashes on your furnace means that it is attempting to … If the failure is internal to the control, the light will stay on continuously. So what does.

Your email address will not be published. Save my name, email, and website in this browser for the next time I comment. Leave a Reply Cancel reply Your email address will not be published.Trane makes gas and electric furnaces as well as air-conditioning equipment for central heating, vent and air-conditioning systems in the home. One of the most common problems that occur on a Trane XR80 gas furnace is its failure to operate. When this happens, the thermostat display may read as active, but turning the heater on does nothing.

Open and close the door until the small flashing red light comes back on to indicate a sealed connection. When the display screen of the thermostat is blank or the unit has no power to it, double check the circuit breaker. Under modern building codes, a furnace must be on its own circuit. Gas furnaces use gas to heat the home but electricity to power the fan and the thermostat and to turn the ignitors on to light the gas.

trane furnace red light flashing

Check the circuit breaker by first flipping it off — as tripped circuit breakers may not appear tripped by visual inspection — and turning it back on. All furnaces require at least a once-a-year inspection or maintenance to ensure adequate operation when you need it most. Part of this process involves removing, cleaning or replacing the air filters inside the cold air return.

trane furnace red light flashing

The cold air return may be a screen on the wall in your home or the filters may be just inside the blower part of the furnace. Remove the screens and clean or replace them. Permanent, plastic-type filter screens can be cleaned, while the paper-framed ones require replacement. Check filters at least every 90 days while the furnace is being used. Depending on your skill level, you may be able to replace the ignitor yourself, but replace it if you have experience, otherwise have a professional handle the repair.

Igniters have a limited life, especially in furnaces that are used regularly.

trane furnace red light flashing

You can expect to replace them at least once every three to five years depending on whether you live in a dry climate, sooner in humid environments. As a native Californian, artist, journalist and published author, Laurie Brenner began writing professionally in She has written for newspapers, magazines, online publications and sites.

Brenner graduated from San Diego's Coleman College. Skip to main content. Home Guides Home Home Improvement. Failure to Operate One of the most common problems that occur on a Trane XR80 gas furnace is its failure to operate. No Power to Thermostat When the display screen of the thermostat is blank or the unit has no power to it, double check the circuit breaker.

Insufficient Heating or Air Flow All furnaces require at least a once-a-year inspection or maintenance to ensure adequate operation when you need it most. About the Author As a native Californian, artist, journalist and published author, Laurie Brenner began writing professionally in Customer Service Newsroom Contacts.Remember Me? Please help. Results 1 to 12 of Thread: Trane xv95 red light flashes 6 times? Thread Tools Show Printable Version. Trane xv95 red light flashes 6 times? I bough this house this year, it was build in The humidifier was not working, then I found out the 24V transformer was dead due to the wrong wire which made it short circuit.

So I bough a new transformer and put it on as the original wire connected. The problem starts. I tried to measure the voltage on the board then found out that the N-line has V voltage. So I checked the wire map details then found out the wire was connected wrong which originally the HUM hot was connected to Line-N wire together. Here is a question why it works originally, even I put the bad transformer back it won't work any more.

Then I connected the wire as the circuit map which Line-N connected with power supplies N line and transformer's N-line. The HUM hot comes from main board connect to transformer's hot line. From this point the mainboard get power but it won't fire up when there is heat calls. The red light flashes 6 times which on the manual says " V AC power revers or igitor fault". Could anyone help to give some clue here?

What Does the Blinking Red Light on My Furnace Mean?

Thanks, Robin. Originally Posted by ziyunxiao. The red light flashes 6 times which on the manual says " V AC power revers or igiter fault". Originally Posted by MM 7. This is above what the rules will allow as far as advice.

The fault code has made it clear where the problem is. You are running the risk of damaging the electronics in the unit so I suggest you turn the power off to the unit and call for service from a local HVAC firm. Tell the tech that comes out about the fault code and what you have replace or changed up to this point. Regards, Heaterman. If you are that leery of getting a poor job from a professional, just keep doing what you're doing.

You should be able to fix it on your own sooner or later. Originally Posted by 2old2rock.